What items need PAT testing?
The short answer is that anything which plugs into the mains and is used at work, or supplied by a landlord, should be looked at. That covers kettles, computers, extension leads, power tools, heaters, fridges and vacuum cleaners.
Not every one of those needs an electrical test, though. The Health and Safety Executive (HSE) is clear that for some equipment a visual inspection is enough.
What an item needs depends on how it is built, how it is used and where. Here is how that works out for the equipment most businesses and landlords have.
What counts as a portable appliance for PAT testing?
HSE describes a portable or movable appliance as any item that can be moved, whether it is connected to the supply or not. These items generally have a lead and a plug.
That takes in more than the name suggests. HSE's guidance lists three broad groups:
- Equipment that is easily moved around, such as kettles, vacuum cleaners, portable heaters, fans, desk lamps, irons, toasters and projectors.
- Larger items that could be moved but rarely are, such as fridges, microwaves, photocopiers, vending machines, washing machines and desktop computers.
- Extension leads, multi-way adaptors and connection leads.
The current IET Code of Practice, the 5th edition published in 2020, goes further. It talks about electrical equipment in general and has dropped the words portable and appliance from the main text. Whether something moves affects how often it should be checked, not whether it is covered.
Which items actually need an electrical test?
The main dividing line is how the item is protected against electric shock.
Class I equipment is earthed. If a fault develops inside, the earth connection is what stops the metal casing becoming live. HSE recommends a portable appliance test for Class I equipment, to confirm that the earth connection is sound.
Class II equipment is double insulated. It does not rely on an earth. HSE's guidance for low-risk environments says Class II equipment will not need a portable appliance test, but user checks and visual inspections should still be done because the casing is the key safety feature.
Class II items carry a symbol of one square inside another. If you cannot find that symbol, HSE says to assume the item is Class I and test it. We explain the difference in full in Class 1 vs Class 2 appliances.
In practice, many businesses have every plug-in item inspected and tested in one visit. It gives a single register and a single set of results, and the visual inspection covers the Class II items anyway.
What does HSE suggest for common office and shop equipment?
HSE's leaflet INDG236 includes a table of suggested initial intervals for low-risk environments such as offices, shops and parts of hotels. These are starting points, not legal rules.
| Equipment | User checks | Formal visual inspection | Combined inspection and testing |
|---|---|---|---|
| Battery-operated, less than 40 volts | No | No | No |
| Extra low voltage, less than 50 volts AC, such as telephone equipment | No | No | No |
| Desktop computers and screens | No | Yes, 2 to 4 years | No if double insulated, otherwise up to 5 years |
| Photocopiers and fax machines, rarely moved | No | Yes, 2 to 4 years | No if double insulated, otherwise up to 5 years |
| Double insulated, not hand-held, such as fans and table lamps | No | Yes, 2 to 4 years | No |
| Double insulated, hand-held, such as some floor cleaners | Yes | Yes, 6 months to 1 year | No |
| Earthed (Class I), such as kettles, irons and some kitchen equipment | Yes | Yes, 6 months to 1 year | Yes, 1 to 2 years |
| Cables, extension leads and battery-charging equipment | Yes | Yes, 6 months to 4 years | Yes, 1 to 5 years |
A workshop, commercial kitchen or building site is a harsher environment and needs more frequent checks than this. See how often should PAT testing be done for more on intervals.
Do extension leads and chargers need PAT testing?
Yes. Extension leads, multi-way adaptors and detachable mains leads are items in their own right. They get moved, stood on, trapped under desks and overloaded, so they fail more often than the equipment plugged into them.
A detachable lead, such as the kettle-style lead on a computer or monitor, is normally tested and labelled separately from the equipment it powers.
Chargers are covered too. HSE's guidance includes mobile phone and other battery-charging equipment that plugs into the mains. The phone or laptop it charges is not included.
What items do not need PAT testing?
Some equipment falls outside PAT testing altogether, or needs nothing more than a look.
- Battery-operated equipment under 40 volts, such as cordless phones and torches.
- Extra low voltage equipment under 50 volts AC, such as telephone equipment and low-voltage desk lights.
- Large items that are wired in and not designed to be moved, such as water boilers. HSE says these come under maintenance of the fixed installation.
- The fixed wiring itself, which means sockets, switches, lighting circuits and the consumer unit.
The fixed wiring is checked by a different inspection, which produces an Electrical Installation Condition Report. The two are often confused, so we have set them side by side in PAT testing vs EICR.
One exception is worth knowing. HSE says a hand-held item that is wired in without a plug, such as a fixed hairdryer in a hotel room or changing room, still counts as a portable appliance.
Does equipment owned by staff or tenants need testing?
At work, yes. HSE's guidance says the duty covers any electrical equipment employees use at work, whether it is their own or supplied by the employer. That includes the phone charger, desk fan or heater someone has brought in from home.
Equipment you lease, such as a photocopier, or equipment a contractor provides for your staff to use, is a joint responsibility. Equipment a contractor both provides and uses themselves is theirs to look after.
Rented homes work differently. In Scotland, the Repairing Standard guidance says the landlord's duty applies to the appliances the landlord provides. Tenants' own appliances are not covered.
How do you work out how many items you have?
Walk round and count everything with a plug, then add the leads. A rough count is fine for a quote.
The items people usually forget are:
- Extension leads and multi-way adaptors under desks.
- Detachable leads on computers and monitors, which count separately.
- Phone and laptop chargers.
- The kettle, microwave, toaster and fridge in the staff kitchen.
- Vacuum cleaners and floor cleaners in the cleaning cupboard.
- Fans and heaters put away for the season.
- Card machines, label printers and radios.
A single desk with a computer, monitor, two leads, a charger and an extension lead can easily come to six items.
How much does it cost to test everything?
Our PAT testing in Dundee is priced per item, with a minimum visit of £74.99 that covers 1 to 30 items. From 31 to 100 items it is £1.59 per item, from 101 to 200 it is £1.49 and from 201 to 500 it is £1.39. The band rate applies to every item, not just the extra ones.
So 60 items would be £95.40 and 120 items would be £178.80. There is no VAT to add and no call-out charge in Dundee. The full price list is on the homepage.
Each item gets a visual inspection, the electrical tests suited to its type, and a pass or fail label with an ID number and retest date. You get a certificate and results PDF by email.
If you have a rough item count, ask for a price or phone 01382 721486. If you are not sure what to count, tell us what kind of premises it is and we can help you estimate.
Sources
- HSE: Maintaining portable electric equipment in low-risk environments (INDG236)
- HSE: Portable appliance testing FAQs
- HSE: Maintaining portable electrical equipment (HSG107)
- IET Wiring Matters: the 5th Edition of the IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment
- Scottish Government: Repairing Standard statutory guidance for private landlords