What is the difference between PAT testing and an EICR?
PAT testing checks the things you plug in. An EICR checks the wiring you plug them into.
They are two separate jobs with two separate reports. A PAT test tells you the kettle, the extension lead and the computer are safe. An EICR (Electrical Installation Condition Report) tells you the consumer unit, cables, sockets and light fittings behind them are safe.
Most workplaces and all let properties need to think about both.
What is the difference between PAT testing and an EICR?
| PAT testing | EICR | |
|---|---|---|
| What it covers | Electrical equipment with a plug, plus its lead | The fixed electrical installation |
| Typical items | Kettles, computers, heaters, power tools, extension leads | Consumer unit, circuits, sockets, switches, light fittings, earthing and bonding |
| What you get | A pass or fail for each item, a label, a certificate and results list | A report with coded observations and an overall satisfactory or unsatisfactory result |
| Standard it works to | IET Code of Practice for In-Service Inspection and Testing of Electrical Equipment | BS 7671, the IET Wiring Regulations |
| How often | Set by risk assessment, often every 1 to 4 years depending on the item | Commonly every 5 years for rented and business premises, 10 for an owner-occupied home |
| Who does it | A competent person with the right test equipment | A skilled person competent in inspecting and testing installations |
| Power off? | Each item is unplugged briefly | Circuits are switched off in turn for testing |
What does PAT testing cover?
PAT stands for portable appliance testing. It covers equipment that connects to the supply with a plug, whether it gets carried about or sits in one place.
HSE's guidance gives a broad list: kettles, vacuum cleaners, heaters, fans, desk lamps, fridges, microwaves, photocopiers, desktop computers, washing machines, extension leads, multi-way adaptors and mains-powered chargers.
Each item gets a visual inspection of the plug, fuse, lead and casing. Depending on how it is built, it then gets electrical tests such as earth continuity and insulation resistance. Our guide to what PAT testing involves covers each step.
A PAT test says nothing about the socket the appliance was plugged into.
What does an EICR cover?
An EICR is the report produced after a periodic inspection and test of the fixed installation. That means everything that is part of the building's electrics:
- The consumer unit or distribution board, with its fuses, circuit breakers and RCDs
- The cables in the walls, floors and ceilings
- Sockets, switches and light fittings
- Earthing and bonding
- Fixed equipment wired into the installation, such as hard-wired heaters and hand dryers
Electrical Safety First says a periodic inspection will reveal whether circuits or equipment are overloaded, find potential electric shock risks and fire hazards, identify defective electrical work, and highlight any lack of earthing or bonding.
The installation is assessed against BS 7671. Each problem found is given a code:
- C1. Danger present. Needs immediate action.
- C2. Potentially dangerous. Needs urgent action.
- C3. Improvement recommended.
- FI. Further investigation required.
An EICR does not test the kettle, the fridge or anything else that is simply plugged in.
Does an EICR include PAT testing?
No. This is the most common mix-up we hear.
An EICR stops at the socket outlet. Appliances plugged into that socket are outside its scope unless appliance testing has been ordered as a separate item on the same visit.
It works the other way too. A full set of green PAT labels tells you nothing about a consumer unit with no RCD protection or a socket circuit with a broken earth.
A simple way to picture it: a safe appliance plugged into an unsafe socket is still a risk, and so is a faulty appliance on perfect wiring.
Do I need both PAT testing and an EICR?
In most workplaces, yes, because the same law applies to both.
The Electricity at Work Regulations 1989 require all electrical systems to be maintained so as to prevent danger. "Systems" covers the fixed installation and the equipment connected to it. The regulations do not name PAT testing or EICRs, but those are the normal ways of showing each part has been looked after.
Here is how it usually works out:
| Who | PAT testing | EICR |
|---|---|---|
| Employers and the self-employed | Yes, as part of maintaining equipment, at intervals based on risk | Yes, as part of maintaining the installation |
| Private landlords in Scotland | Yes, for appliances the landlord supplies | Yes, at intervals of no more than five years |
| Homeowners living in their own home | No duty | No duty, but recommended every 10 years |
If you rent your business premises, check your lease. The landlord often looks after the fixed installation while the tenant looks after everything plugged in, but leases differ.
How often do you need PAT testing compared with an EICR?
EICR. Electrical Safety First recommends a periodic inspection every 10 years for an owner-occupied home and every 5 years for a rented home. For workplaces, HSE does not give a fixed number. It says installations should be tested often enough that there is little chance of deterioration leading to danger. Five years is the figure most often used for offices and shops, and the person carrying out the inspection will recommend the next date on the report.
PAT testing. There is no fixed legal interval. HSE's suggested starting points for low-risk workplaces range from every 1 to 2 years for earthed items such as kettles, to visual inspection only for many double insulated items. The IET Code of Practice removed its table of fixed intervals in its 5th edition in 2020 and now expects a risk assessment.
So appliances are normally checked more often than the wiring. They are moved, dropped, coiled up and plugged in and out, and fixed wiring is not. How often PAT testing should be done covers the detail.
Do landlords in Scotland need PAT testing and an EICR?
Yes, private landlords in Scotland need both.
The Repairing Standard requires the electrical installation in a let property to be inspected at intervals of no more than five years. The Scottish Government's statutory guidance says an EICR completed by a suitably competent skilled person meets that requirement.
The same guidance covers appliances the landlord has supplied, such as fridges and washing machines. These are inspected and tested, with the records attached to the EICR. The guidance says appliance retesting will usually be more frequent than every five years. Appliances that belong to the tenant are not part of the landlord's duty.
This is why the two jobs are often booked together for a let flat. We go through the landlord rules in do landlords need PAT testing in Scotland.
How much does PAT testing cost compared with an EICR?
The two are priced in different ways.
PAT testing is priced by the number of items. Our minimum visit is £74.99 for 1 to 30 items. After that it is £1.59 per item for 31 to 100, £1.49 for 101 to 200 and £1.39 for 201 to 500, with the band rate applied to every item. There is no VAT to add and no call-out charge in Dundee. See the price list for the full table.
An EICR is priced by the size of the installation, mainly the number of circuits, and is quoted for the property. EICRs are handled by our parent business, Dundee Sparks, so speak to a Dundee electrician there if the wiring is due.
Our PAT testing in Dundee is carried out by a qualified electrician and also covers Broughty Ferry, Monifieth, Carnoustie, Invergowrie, Newport-on-Tay, Tayport and nearby. Every item gets a pass or fail label with an ID number and retest date, and you receive a certificate and a results PDF by email, with a reminder when the retest is due.
To get a figure for the appliance side, ask for a price or phone 01382 721486.