Do landlords need PAT testing in Scotland?
Yes. If you let a home privately in Scotland and you supply any electrical appliances with it, you have to have them inspected and tested.
The duty comes from the Repairing Standard in the Housing (Scotland) Act 2006. The Scottish Government's statutory guidance says landlords who provide electrical equipment must organise regular in-service inspection and testing, which it notes is also known as PAT testing.
This is stricter than the general position for UK workplaces, where PAT testing is not named in law at all. Housing law is devolved, so the rules for private landlords in England, Wales and Northern Ireland are set separately. If you own property outside Scotland, check the rules for that country.
Is PAT testing a legal requirement for landlords in Scotland?
In practice, yes.
The Repairing Standard says that any fixtures, fittings and appliances provided by the landlord must be in a reasonable state of repair and in proper working order. Landlords must also make sure an electrical safety inspection is carried out.
The statutory guidance says that inspection has two parts:
- An inspection and test of the fixed electrical installation, recorded on an Electrical Installation Condition Report (EICR)
- Inspection and testing of the appliances the landlord has supplied, which is the PAT testing
You are not required to supply appliances. But once you do, they are your responsibility.
How often do landlords need PAT testing in Scotland?
The electrical safety inspection must be done before a tenancy starts, and then during the tenancy at intervals of no more than five years from the date of the last inspection.
Five years is the longest gap allowed. The guidance notes that retest dates for appliances will usually be more frequent than that. An appliance that already has a current test does not need to be tested again just because the EICR is being done.
There is no fixed shorter interval in the guidance. Landlords commonly choose one of these:
| Approach | When it suits |
|---|---|
| At each change of tenant | Long lets where appliances get little wear between tenants |
| Every year | Student flats, HMOs and furnished lets with a lot of appliances |
| Every two years or so | Lightly furnished lets with a few newer appliances |
| With the EICR, every five years at most | The legal backstop, not a recommendation |
The retest date on each label tells you when that item is next due. More detail on intervals is in how often PAT testing should be done.
What is the difference between an EICR and PAT testing for landlords?
They cover different things, and you need both.
| EICR | PAT testing | |
|---|---|---|
| What it covers | The fixed installation, including the consumer unit, wiring, sockets, switches, light fittings and fixed equipment | Appliances the landlord supplies that plug in or can be moved |
| What you get | An Electrical Installation Condition Report with coded observations | An equipment register, test results and a label on each item |
| Who can do it | A skilled person competent in inspection and testing, as set out in the guidance | A skilled electrical person, or someone who has completed appropriate training |
| How often | At least every five years | Regularly, and at least every five years |
The guidance says the PAT records should be attached to the EICR, so the two sit together as the record of your electrical safety inspection.
We explain the two in more depth in PAT testing vs EICR.
Which appliances does a landlord need to PAT test?
Any electrical equipment you supply that is not permanently wired into the building. The guidance lists:
- White goods, such as fridges, freezers and washing machines
- Brown goods, such as televisions
- Electric fires that are not fixed in place
- Kitchen appliances, such as kettles, toasters and microwaves
- Hand-held equipment, such as hairdryers
- Anything else you provide that plugs in, including vacuum cleaners, lamps and extension leads
Fixed equipment, such as a wired-in cooker, shower or storage heater, is dealt with as part of the EICR.
A tenant's own appliances
These are not yours to test. The guidance is clear that the duty covers appliances provided by the landlord and does not apply to appliances that belong to tenants. A written inventory of what you supplied avoids confusion later.
New and second-hand appliances
The guidance says equipment that was bought new less than one year before the date of the test does not need to be included. It should still be added to the equipment register, with a date for its first test.
Second-hand appliances are different. The guidance says the landlord must verify that any second-hand equipment is safe, which means having it inspected and tested before it goes into the property.
Keep receipts for new appliances so you can show when they were bought.
Who can do PAT testing for landlords in Scotland?
The guidance says PAT testing for the Repairing Standard must be done by either:
- A skilled electrical person, or
- A person, including the landlord, who has completed appropriate training as a competent person
So a landlord can legally test their own appliances, but only after completing suitable training. They also need a proper test instrument and have to produce the records. If that route interests you, read can I do my own PAT testing.
The EICR is a separate matter. It has to be done by a skilled person competent in inspecting and testing fixed installations, and the guidance sets out how a landlord should check that.
Our PAT testing is carried out by a qualified electrician.
What records does a Scottish landlord need to keep?
The guidance says the PAT records should include an equipment register and a record of the inspection and test for each item. Items that pass can be confirmed with a record and a label showing they are satisfactory for continued use.
For the EICR, the landlord must keep a copy for six years. A copy of the most recent report must be given to a new tenant before the tenancy starts, and if an inspection is carried out during a tenancy the tenant must be given a copy of that report.
Tenants cannot be charged for the inspection.
Every job we do includes a label on each item with an ID number and retest date, plus a certificate and a results PDF by email to file with your EICR.
Do short-term lets and holiday lets need PAT testing in Scotland?
Yes. Short-term lets in Scotland need a licence, and one of the mandatory licence conditions covers electrical safety.
The licence holder must arrange for a competent person to inspect the electrical fittings and items at least every five years, or more often if that person directs. They must have a Portable Appliance Testing Report on moveable appliances that guests have access to, as well as an EICR for the fixed installation. Inspected appliances must be labelled with the date and signed.
Councils can add their own conditions on top of the mandatory ones. If you let in Dundee or Angus, check your licence and the council's guidance. HMO licences come with their own council conditions as well, so check those too.
What happens if a landlord does not PAT test?
If a rented home does not meet the Repairing Standard, the tenant can apply to the First-tier Tribunal for Scotland (Housing and Property Chamber). The Tribunal can order the landlord to carry out the work needed.
Short-term let hosts risk breaching their licence conditions, which can lead to a fine or loss of the licence.
If an appliance fails our test, we label it as failed, take it out of use and explain what is wrong. The guidance says failed equipment must be replaced or repaired immediately, so that part is for you to arrange.
What landlord PAT testing costs in Dundee
Most rented flats and houses have fewer than 30 landlord appliances, so they fall under our minimum visit of £74.99. There is no VAT to add and no call-out charge in Dundee.
Landlords with several properties can book them together. The full price list shows the per-item rates for larger counts.
We offer landlord PAT testing in Dundee, Broughty Ferry, Monifieth, Carnoustie, Invergowrie, Newport-on-Tay, Tayport and nearby, with evening and weekend visits to suit tenants. To book, ask for a price or call 01382 721486.
This article is general guidance, not legal advice. Check the statutory guidance below for the full wording.
Sources
- Scottish Government: Repairing Standard statutory guidance for private landlords, Annex D3 (electrical installations)
- Scottish Government: Repairing Standard statutory guidance for private landlords, Annex E (appliances)
- The Civic Government (Scotland) Act 1982 (Licensing of Short-term Lets) Order 2022, Schedule 3
- mygov.scot: Legal requirements for a short-term let licence